Successful Treatment of Multiple Superficial Gastric Antral Bleeding with Alto Shooter(TM) in a Patient with End Stage Renal Disease.
- Author:
Kee Sup SONG
1
;
Jun Pyo CHUNG
;
Ju Ik SOHN
;
Jun Hee LEE
;
Ki Joon HAN
;
Se Joon LEE
;
Hyo Jin PARK
;
Byung Soo MOON
;
Kwan Sik LEE
;
Sang In LEE
;
Jin Kyung KANG
;
In Suh PARK
Author Information
1. Department of Internal Medicine, Yonsei University, College of Medicine, Seoul, Korea. chungjp@yumc.yonsei.ac.kr
- Publication Type:Case Report
- Keywords:
Alto Shooter(TM);
Sodium alginate;
Gastrointestinal bleeding
- MeSH:
Argon Plasma Coagulation;
Biopsy;
Electrocoagulation;
Hemorrhage*;
Humans;
Kidney Failure, Chronic*;
Middle Aged;
Sodium
- From:Korean Journal of Gastrointestinal Endoscopy
2001;22(6):431-434
- CountryRepublic of Korea
- Language:Korean
-
Abstract:
Diffuse or multifocal superficial gastrointestinal bleeding can be treated by endoscopic laser, argon plasma coagulation, heater probe, or electrocoagulation. However, these methods need relatively expensive equipments and clinical experience. Recently, Alto Shooter(TM) (Kaigen Co. Ltd., Osaka, Japan) which can spray 100% sodium alginate was developed to control gastrointestinal bleeding as a topical therapy. We herein present a 47-year-old man with end stage renal disease in whom multiple superficial gastric antral bleeding was successfully managed by the use of Alto Shooter(TM). This method is easy and relatively cheap to use and seems to control superficial bleeding effectively from vascular lesions or after endoscopic biopsy.