Study on Serum Dilution in Detecting Anti HBc-IgM with ELISA
- VernacularTitle:关于酶联法检测抗HBc-IgM时血清稀释度的探讨
- Author:
Chunqing WU
;
Ming XIE
;
Qifen LI
- Publication Type:Journal Article
- From:Journal of Third Military Medical University
1983;0(04):-
- CountryChina
- Language:Chinese
-
Abstract:
A study on the optimal dilution of serum to detect anti HBc-IgM with ELISA. was carried out. Samples were diluted to 10-1to 10-7. Among 26 samples of normal individuals, 22 were negative, but two samples of 10-1 dilution, one sample of 10-2, and one sample of 10-1-10-3 were positive though the control wells were all negative. 42 samples of the patients with variours types of hepatitis B were examined. It was found that when serum dilution was 10-1, only 6 cases were positive; when the dilution was 10-2, 20 cases were positive; when the dilutions were 10-3, 5?10-3, and 10-4, high positive rates were obtained and they were 88.1%, 78.5%, and 69% respectively; and when the samples were further diluted, the positive rate decreased.In order to get goodfresults and minimize false results, either false negative or false positive, it is suggested that 5?10-3 be the optimal dilution.