Comparison of cannulated compression screws and dynamic hip screws in fixation for aged patients with intertrochanteric hip fractures
- VernacularTitle:加压空心螺钉与动力髋螺钉治疗老年性股骨转子间骨折的疗效对比
- Author:
Haibo ZHAO
;
Xiangyu CAI
;
Feng ZHANG
- Publication Type:Journal Article
- Keywords:
intertrochanteric hip fracture;
cannulated compression screw;
dynamic hip screw;
fracture fixation,internal;
retrospective study
- From:
Orthopedic Journal of China
2006;0(16):-
- CountryChina
- Language:Chinese
-
Abstract:
[Objective]To compare the fixation effects of cannulated compression screws and dynamic hip screws.[Method]From July 2000 to December 2006,152 old patients with intertrochanteric hip fracture were fixed with cannulated compression screws(n=68) and dynamic hip screws(n=84).They were followed up and their complete clinic data were obtained.A retrospective comparison was made between the two differet fixation devices in terms of operation time,blood loss,intraoperative and postoperative complications,functional recovery one year postoperatively and treatment expenses.[Result]The differences in operation time,blood loss between 2 groups had statistical significance(P0.05) for the Evans types Ⅰ,Ⅱ patients,but had statistical significance(P