Treatment of the unstable intra-articular fractures of the distal radius with LCP internal fixation
- VernacularTitle:锁定加压钢板内固定治疗桡骨远端C型骨折
- Author:
Qiang LU
;
Hua CHEN
;
Meng XU
- Publication Type:Journal Article
- Keywords:
fracture of the distal radius;
locking compression plate;
fracture healing
- From:
Orthopedic Journal of China
2006;0(22):-
- CountryChina
- Language:Chinese
-
Abstract:
[Objective]To evaluate the therapeutic effect of treating AO type C fracture of the distal radius with open reduction LCP plate internal fixation.[Method]From Jan.2004 to Jan.2007,37 cases of AO type C fractures of the distal radius were treated with LCP plate internal fixation.All cases were fixated through volar approach,the length of radius,waist joint angle were recovered,screwed the plate,the exposure of dorsal soft tissues could be obtained by internal-rotate radius,allo-bone graft,and aoto-bone graft was necessary for the case with bone defect.Passive wrist motion,active finger motion and forearm rotation were encouraged immediately after surgery.Active wrist motion was suggested seven days postoperatively.[Result]The 37 cases were followed up for 8 to 21 months,with an average time of 11 months.X-ray pictures showed that one-stage union was achieved in the patients,with a mean healing time of eight weeks.No such complications were found as infection,non-union,loosing of nails,carpal tunnel syndrome or medium neuritis.Their clinical outcomes were evaluated according to modified McBride grading system.Twenty-five were rated as being excellent,eight as good and four as fair,with their good-excellent rate as being 89.18%.[Conclusion]Treatment of type C distal radius fracture with LCP plate internal fixation has many advantages,such satisfactory reduction,rigid fixation,and excellent function.