CT-guided Percutaneous Transthoracic Aspiration Biopsy for Pulmonary Lesions:Comparison between Lesion Size and Depth
- VernacularTitle:CT导引下肺内病变穿刺活检:不同大小和不同深度病灶间的比较
- Author:
Zhenguo HUANG
;
Xuezhe ZHANG
;
Wu WANG
- Publication Type:Journal Article
- Keywords:
chest;
interventional radiology;
biopsy;
needle aspiration;
pneumothorax
- From:
Journal of Practical Radiology
2001;0(10):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective To evaluate the influence of lesion size and depth on the diagnostic accuracy and the rate of pneumothorax in patients undergone CT-guided transthoracic aspiration biopsy for pulmonary lesions.Methods CT-guided percutaneous transthoracic biopsy was performed in 398 patients that had surgical resection or clinical follow-up.According to lesion size,lesions were divided into≤2 cm,2~4 cm and ≥4 cm.Lesion depth was measured from the pleura surface to the edge of the lesion.This depth was classified in three categories:≤1 cm,1~3 cm and ≥3 cm.Comparison of the diagnostic accuracy and the frequency of pneumothorax in different size and depth of lesion was performed.Results(1)The overall diagnostic accuracy of CT-guided percutaneous needle aspiration biopsy was 83.2%(331/398).Pneumothorax occurred in 58(14.6%)of 398 biopsy;(2)The diagnostic accurate rate in different size of lesion was 73.3%(44/60),81.5%(176/216)and 91.0%(111/122)respectively,?2=9.91,P0.05.The occurred rate of pneumothorax in different depth lesion was 2.8%(4/141),14.8%(21/142)and 28.7%(33/115),?2=34.03,P