Relationship between Concentration of t, t-2, 4-DDE in Cooking Oil Fume and Cooking Temperature
- VernacularTitle:烹调油烟中反,反-2,4-癸二烯醛浓度与油温的关系
- Author:
Jianrong CHAI
;
Zheng RUAN
;
Zhongbo YU
- Publication Type:Journal Article
- Keywords:
Air pollution, indoor;
Cooking oil fumes;
Trans, trans-2, 4-decadienal
- From:
Journal of Environment and Health
2007;0(10):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective To explore the relationship between the concentration of t, t-2, 4-DDE in cooking oil fume(COF) and the cooking temperature. Methods The temperature control system of oil heating was developed, the activated carbon was used to collect gaseous pollutants. Six samples were prepared at 60, 90, 120, 150, 180, 210, 240 and 270 ℃. The concentration of t, t-2, 4-DDE in COF was analyzed by GC-FID. Results The concentration of t, t-2, 4-DDE in COF was below the detection limit when the oil temperature was not higher than 120 ℃. Among the 150 ℃ and 270 ℃ groups, the concentration of t, t-2, 4-DDE showed a significant increase. Conclusion The concentration of t, t-2, 4-DDE in COF may obviously increase as the cooking temperature is not lower than 150℃.