Comparative Study of ~(18)F-FDG PET-CT and ~(99)T_c~m-MDP Bone Scan in Detecting Bone Metastases
- VernacularTitle:~(18)F-FDG PET-CT与~(99)T_c~m-MDP骨显像对骨转移瘤诊断价值的对比研究
- Author:
Guangli WANG
;
Chengqi ZHANG
;
Shuzhan YAO
;
Qingwei LIU
;
Jing CHEN
- Publication Type:Journal Article
- Keywords:
tomography ,emission computed;
radionuclide imaging;
skeleton;
metastatic tumor
- From:
Journal of Practical Radiology
2001;0(08):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective To compare the diagnostic value of PET-CT and bone scintigraphy in bone metastases. Methods Thirty-two patients with malignant neoplasm confirmed by pathology were undergone18F-FDG PET-CT and bone scan within two weeks.The sensitivity,specificity and accuracy of PET-CT and bone scan in detecting the focus were compared at the same scan filed.Results The diagnostic sensitivity,specificity and accuracy with PET-CT were 94.9%,91.7% and 94.1%,respectively,and 96.2%,54.2% and 86.3% with bone scan,respectively.18F-FDG PET-CT and99Tcm-MDP bone scan were the same in detecting metastatic tumor of bone,but the specificity of18F-FDG PET-CT was better than99Tcm-MDP bone scan in detecting bone metastasis.Conclusion Compared with99Tcm-MDP bone scan,18F-FDG PET-CT is more specific and helpful in detecting bone metastases.