Clinical Application of the Alginate Microglobe Particles in Partial Splenic Embolization for Hypersplenism in Cirrhosis
- VernacularTitle:褐藻胶微球在部分性脾栓塞术中的应用评价
- Author:
Zhiming HE
;
Xiaodong XIE
- Publication Type:Journal Article
- Keywords:
spleen;
hypersplenism;
embolization;
alginate microglobe
- From:
Journal of Practical Radiology
1991;0(03):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective To elevate the efficacy and complications of partial splenic embolization(PSE) using the alginate microglobe(AMG) as embolic material for hypersplenism in cirrhosis.Methods 42 patients with hypersplenism and cirrhosis were treated by PSE,AMG of 250~450 ?m were injected into the arteries of inferior splenic pole,the embolization degree was ranging from 40% to 70%.Results 42 times of embolization were performed in 42 patients,after operation, 35 patients had fever and lasted for 3~15 d,38 patients had abdominal pain,of them, 27 patients needed treatment with analgesic.Treatable a little hydrothorax appeared in 6 ,and no serious complication occurred.WBC and PLT counts were increased 24 hour later(P