Bionic bone implantation combined with limited contracted titanium net duct on the repairment of rabbit bone defect
- VernacularTitle:仿生骨植入钛网管固定修复兔骨缺损
- Author:
Kaifang ZHANG
;
Hongwei YAN
;
Kai LIU
;
Tao LIU
- Publication Type:Journal Article
- Keywords:
bionic bone;
titanium net duct;
bone defect;
repair;
rabbit
- From:
Journal of Xi'an Jiaotong University(Medical Sciences)
1982;0(01):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective To investigate the effect of MHA-bBMP implantation combined with limited contacted titanium net duct fixation on femoral shaft bone defect in rabbits.Methods A total of 48 rabbits were divided into experimental group(treated with bionic bone MHA-bBMP plus titanium net duct) and control group(treated with iliac autograft plus titanium net duct).The rabbit femoral shaft bone defect model was established by cutting 10mm bone fragment off.After operation,bionic bone MHA-bBMP/iliac autograft was implanted into the bone defect area and fixed with limited contacted titanium net duct.The general condition,serum alkaline phosphates,X-ray,histopathologic and electron microscopic examinations were performed.Results The fixation stability of titanium net duct in the two groups was good.The bone defect in the two groups was repaired.The phosphates,X-ray,histopathologic and electron microscopic examinations in the two groups were not significantly different.Conclusion The limited contacted titanium net duct can provide a reliable fixation effect on the graft and bone defect ends.Induction bone formation activity of MHA-bBMP is comparable to the iliac autograft.