Determination of Chloroform and Tetrachloromethane in Drinking Water with Different Capillary Columns
- VernacularTitle:3种毛细管色谱柱在水中氯仿和四氯化碳测定中的应用
- Author:
Yongbo LI
;
Rong GUAN
;
Hongguang LI
- Publication Type:Journal Article
- Keywords:
Water Chromatography, gas Capillary column Chloroform Tetrachloromethane
- From:
Journal of Environment and Health
1993;0(01):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective To explore the feasibility for determination of chloroform and tetrachloromethane in drinking water with DB-5, Rtx-1 and DB-1 capillary columns. Methods For the mild solubility of chloroform and tetrachloromethane in drinking water, chloroform and tetrachloromethane were analysed by static headspace gas chromatography with DB-5, Rtx-1 and DB-1 capillary columns and electron capture detectorECD, external standard method was used for quantification. Results Three kinds of columns were used for determination of chloroform and tetrachloromethane,the retention time was lower than 3 min, for chloroform and tetrachloromethane the average recovery rates were 92.06%-104.95% and 78.33%-103.22% respectively, RSD were 2.06%-2.71% and 1.76%-5.59% respectively. Conclusion DB-5, Rtx-1 and DB-1 capillary columns are suitable for determination of chloroform and tetrachloromethane in drinking water.