Clinical value of MSCT scanning and three-dimensional reconstructing well-liking shinbone prefabricating internal plate to repair catagmatic shinbone
- VernacularTitle:MSCT扫描重建健侧胫骨在患侧内固定材料塑形中的意义
- Author:
Basheng HU
;
Changqing ZHAO
;
Xuelin ZHANG
- Publication Type:Journal Article
- Keywords:
multi-slice helical CT;
three-dimensional reconstructing;
blade plate;
shinbone
- From:
Orthopedic Journal of China
2006;0(20):-
- CountryChina
- Language:Chinese
-
Abstract:
[Objective]To explore a new technique of prefabricating internal plate.[Method]Three-dimensional reconstruction of the well-liking shinbone was performed by MSCT scanning and the length and shape of the catagmatic shinbone for operation was measured on well-liking shinbone.The shinbone curve was depicted using a self-designed skeletal curve-depicting.Then shape of the material for internal fixation was determined.[Result]The length and shape of the shinbone curve was accurately measured.The physiological curve of the shinbone was depicted.Then shape of the material for internal fixation was determined.[Conclusion]Three-dimensional well-liking shinbone reconstruction with MSCT and measurement facilitates the determination of the optimal length and shape of the internal fixation material to enhance the attachment between the material and the bone surface and consequently the therapeutic effects.One case's length and shape of internal fixation was dissatisfactory for hyperplasia of bone.But the length and shape of internal fixation has basal shape.