Determination of Five Anions in Drinking Water by Ion Chromatography
- VernacularTitle:饮用水中5种阴离子的离子色谱测定法
- Author:
Liqun QIAN
;
Ningying LIU
;
Chunlan CHEN
- Publication Type:Journal Article
- Keywords:
Water;
Chromatography, ion exchange;
Anions
- From:
Journal of Environment and Health
1992;0(05):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective To develop a conductance-ion chromatography for simultaneous determination of 5 anions in drinking water. Methods The orthogonal experiment method L9(34) was used to select the optimum working conditions of IC-2000 ion chromatography. Under the founded chromatography condition, 5 anions in water samples were determined simultaneously after filtered with 0.45 ?m filter membrane. Results Both of the precision and accuracy of this method were desirable, all the relative standard deviation was less than 5.0%, the rates of recovery were 90%-106.7%, the correlation coefficient was more than 0.999 except NO2-(0.990 5). Conclusion This method is simple, accurate, quick and suitable for simultaneous determination of 5 anions in drinking water with no need of sample pretreatment.