Biomechanical study and application of lateral-anterior internal fixation with TSRH in thoracolumbar fracture
- VernacularTitle:脊柱胸腰段骨折侧前方TSRH固定的生物力学研究及应用
- Author:
Zhenhua JIANG
;
Xiangdong CHEN
;
Feng ZHANG
- Publication Type:Journal Article
- Keywords:
Thoracolumbar fracture;
TSRH lateral-anterior internal fixation;
Biomechanics;
Application
- From:
Orthopedic Journal of China
2006;0(06):-
- CountryChina
- Language:Chinese
-
Abstract:
0.05).[Conclusion]Lateral-anterior fixation with use TSRH not only has effective result in strength, rigidity and stability of the spine, but also is superior to the control group in loading-bearing ability and stability of the spine. There is no significant difference between the TSRH group and Z-plate group. But TSRH is relatively simple to operate and is cheaper than Z-plate, and has exact clinical ontcome.