Development of an electrocircuit controlled impact device for injuring spinal cord in adult rats
- VernacularTitle:电控大鼠脊髓损伤打击器的研制
- Author:
Rutong YU
;
Qiping WANG
;
Demo WU
- Publication Type:Journal Article
- Keywords:
Spinal cord injury: Model;
Impact device
- From:
Chinese Journal of Trauma
1993;0(05):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective To develop a new impact device that can cause different levels of spinal cord injury in adult rats so as to provide a scientific means for standard spinal cord injury model in adult rats. Methods First, two laser heads were installed beside the impacting hammer in order to define the dropping point of imparting hammer through the focus of the two tracts of lasers. A height controlled electrocircuit was designed to control the rotation of the minitype dynamo that regulated the height of impacting hammer precisely via the worm gear. Meanwhile, a time controlled electrocircuit was made so as to secure that the process of injury could be finished within 10 millionseconds constantly according to the technique of weight dropping and the principle of electromagnetic electromagnetism respectively. Results The present impact device could produce different levels of spinal cord injury in adult rats within special times, heights and dropping points. Conclusion We have successfully produced an electro-circuit controlled impact device with laser defining position that is simple and easy to use for making controllable and precise injury models.