The effects of microarc oxide treatment on the bonding strength of titanium to ceramic
- VernacularTitle:钛表面微弧氧化处理对钛瓷结合强度的影响
- Author:
Xiaojie WANG
;
Tianwen GUO
;
Yumei ZHANG
- Publication Type:Journal Article
- Keywords:
Microarc oxidation;
Ttitanium;
Porcelain;
Bond strength
- From:
Journal of Practical Stomatology
1996;0(02):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To study the feasibility of microarc oxide treatment on the enhancement of titanium-ceramic bonding strength. Method:Titanium samples in the size of 25 mm?3 mm?0.5 mm were prepared with smooth surface(group 1),rough surface(group 2) and microacrc oxide treated surface(group 3). Nickel-chromium alloy samples in the same size were prepared (group 4). The surface of the samples was observed by scanning electron microscope(SEM) and dispersive spectrometry analysis. Then, the samples were bonded to porcelain. The bonding interface was observed by SEM. The bonding strength of the samples was measured by a three-point bending test according to ISO 9693.Results:Microarc oxide treated surface was rough and porous. The interface of microarc oxide treated surface bonded to porcelain was compact. The bonding strength(MPa) of the samples of group 1,2,3 and 4 to porcelain was 30.79?1.3,36.12?3.03,45.84?3.15 and 48.35?3.06 respectively(group 3 vs group 1 or 2 P0.05). Conclusion:The microarc oxide treatment on titanium can increase the titanium-ceramic bond strength.