Disinfection for Pure Water Produced by Household RO Purifier
- VernacularTitle:消毒装置对家用反渗透纯水机出水的消毒效果
- Author:
Yongzhang PAN
;
Lahua JIN
;
Na ZHANG
- Publication Type:Journal Article
- Keywords:
Water purification;
Disinfection;
Ultraviolet rays
- From:
Journal of Environment and Health
1992;0(02):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective To study the relationship between static duration and bacteria reproduction of pure water from the RO purifier. Methods The original structure of RO purifier was modified by installing additional UV lights and ozone disinfector respectively. Bacteria reproduction in the effluent from RO purifier and modified RO purifier was detected after different static duration. Results The total count of bacteria in the fresh pure water was 20 cfu/ml which was up to the standard of pure drinking water CJ 94-1999. However the total count of bacteria in the pure water will be more than 50 cfu/ml after the pure water was stored inside the tank for six hours, which was not up to the standard of CJ 94-1999. Both ultraviolet rays and ozone could prolong the static duration of pure water, and the efficacy of ultraviolet rays was better than ozone. Conclusion UV light should be installed in RO purifier, the disinfected pure water by UV should be used in 16 hours after disinfection.