Determination of Acetic Acid Peroxide in Disinfectant by Gas Chromatography
- VernacularTitle:消毒液中过氧乙酸的气相色谱测定法
- Author:
Jinsheng HAN
;
Wenlong SUN
;
Aihong YUAN
- Publication Type:Journal Article
- Keywords:
Chromatography,gas;
Disinfection;
Acetic acid peroxide
- From:
Journal of Environment and Health
1989;0(06):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective To established a method for determining the acetic acid peroxide in disinfectant. Methods The acetic acid peroxide determined by gas chromatography using FFAP fixative solution, Chromosorb W-AW DMCS column and FID detector. Results The detection limit was 0.001%.The linear range was from 0.01% to 25%.The recovery rate was 93%-102%?RSD was less than 2.93%. Conclusion The method is simple, rapid, sensitive and has a good selectivity. The sample can be directly detected without separation.