Hepatic integrated backscatter in healthy rabbits
- VernacularTitle:正常家兔肝超声背向散射积分研究
- Author:
Yuemin NAN
;
Ruijun GUO
;
Xixian YAO
- Publication Type:Journal Article
- Keywords:
Ultrasonography;
Liver;
Rabbit;
Integreted backscatter
- From:
Chinese Journal of Ultrasonography
1993;0(04):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective To measure hepatic ultrasonic integrated backscatter (IBS) in healthy rabbits as a non-invasive quantitative diagnostic means for hepatic steatosis, hepatic fibrosis, and liver cirrhosis; to determine the factors that may influence the IBS measurement. Methods Thirty-five healthy New Zealand white rabbits with normal liver function tests and normal liver biopsies were used in this study. HP Sonos 5500 image system with quantitative analysis function was used for IBS measurement. With the machine setting fixed, and optimal image obtained, left and right liver were divided into near, medial and far areas according to the depth. Further the measurements of IBS in different depth were performed respectively. Meanwhile, in the same liver the IBS image was collected and the change of IBS intensity was measured in various setting of machine index (MI), time gain compensation (TGC) and lateral gain compensation (LGC). Results Average image intensity (AII) of left liver (from near to far areas) was ( 25.38? 2.36)dB, ( 26.32? 2.38)dB, and ( 26.45? 2.28)dB, respectively. The AII of the right liver (from near to far areas) was ( 24.99? 2.23)dB, ( 24.92? 2.59)dB, and ( 25.38? 2.36)dB, respectively. The average standardized AII of image in left livers was significantly higher than that of the right (P