Combined Toxicity of Volatile Organic Compounds and Ammonia in Indoor Air
- VernacularTitle:居室空气中挥发性有机物与氨的联合毒性
- Author:
Chaoyan OU
;
Jinshun ZHAO
;
Hong YANG
- Publication Type:Journal Article
- Keywords:
Indoor air: Volatile organic compound: Ammonia: Toxicity
- From:
Journal of Environment and Health
1993;0(01):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective To explore the combined toxicity of dominant volatile organic compounds(VOCs) and ammonia in indoor air of newly decorated rooms.Methods The gaseous mixture of several main components of VOCs and ammonia was prepared using their pure chemical reagents based on the percentage of mass proportion to each pollutant calculated by the medians of concentrations of formaldehyde,benzene,methylbenzene,dimethylbenzene,ethylbenzene and ammonia obtained from the in situ monitoring data on indoor air of 45 newly decorated apartments.The Kunming mice were exposed to the prepared gaseous mixture at doses of 3.93,8.47,18.24 and 39.35 g/m3 for acute toxicity test,and at doses of 3.935 g/m3(higher dose),1.970 g/m3(middle dose)and 0.393 g/m3(lower dose)for sub-acute toxicity test respectively.Results The LC50 of the prepared gaseous mixture was 26.84 g/m3 for Kunming mice.The sub-acute toxicity test showed that the lower levels of reticulocyte count of female mice in each dose group,the lower level of HCT of female mice dose group,the lower levels of PLT in serum of female and male mice in higher dose group,higher activity of ALT in serum of female mice in higher dose group showed significant differences compared with those of controls (P