Determination of Pb and Cd in Sewage by Linear Sweep Anodic Stripping Voltammetry
- VernacularTitle:污水中铅镉的溶出伏安测定法
- Author:
Yuanzhi SONG
;
Binghua LIU
;
Meixia CHEN
- Publication Type:Journal Article
- Keywords:
Sewage;
Lead;
Cadmium;
Linear sweep anodic stripping voltammetry
- From:
Journal of Environment and Health
1992;0(04):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective To establish a new method for determination of Pb and Cd in sewage.Methods The contents of Pb and Cd in sewage were simultaneously determined by linear sweep anodic stripping voltammetry in0.1mol/L HCl -0.1mol/L KCl solution.Results The peak potentials of Pb and Cd appeared at-588mV and-780mV respectively.The recovery rates and precisions(RSD%)of Pb and Cd were90.0%-110.0%,91%-109.5%and0.41%-4.24%,0.56%-7.03%respectively.The lin-ear range of Pb and Cd was0.005-0.2mg /L.Conclusion This method could be applied for determination of Pb and Cd in sewage.