The Diagnosis and Clinical Value of Spiral CT in Orbital Blowout Fracture
- VernacularTitle:眼眶爆裂骨折的螺旋CT诊断及临床价值
- Author:
Jizhou YANG
;
Jingliang CHENG
- Publication Type:Journal Article
- Keywords:
orbital fracture;
tomography ,X-ray computed;
multiplanar reconstrucions
- From:
Journal of Practical Radiology
2001;0(05):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective To discuss the diagnosis and clinical value of spiral CT(SCT) in orbital blowout fracture.Methods The SCT MPR findings in conjunction with transaxia images in 120 cases of orbital blowout fracture were retrospectively analyzed. According to the this analysis,108 patients were treated conservatively only 12 were under the opereation.Results Interruption of bone continuity, fragments, depression and displacement of orbital bone wall were direct signs of orbital blowout fracture." Tear drop"sign in the maxillary or ethmoid sinus was a characteristic indirect sign of inferior or medial orbital wall fracture. Enophthalmos obviously compacting of extraocular muscler and distraction test male were operation signs.Conclusion Orbital blowout fracture can be diagnosed by SCT volume scanning findings of the MPR comprehensively and accurately, that is very important in choosing the treatment methods for orbital blowout fracture.