Finite element analysis of the stress induced by an endodontic endosseous implant placed through a centeral incisor with periodontal compromises
- VernacularTitle:根骨内种植体植入牙槽骨吸收的中切牙的有限元应力分析
- Author:
Chunbao ZHANG
;
Xuanxiang MA
;
Shaofeng ZHANG
- Publication Type:Journal Article
- Keywords:
Endodontic endosseous implant;
Stress;
Finite element analysis
- From:
Journal of Practical Stomatology
1996;0(02):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective: To study the stress in bone implant interface, dentin and periodontal ligament while an endodontic endosseous implant is placed through a centeral incisor with periodontal compromises. Methods: Two dimension finite element analysis method was used and finite element analysis (FEA) model of the Chinese adult central incisor with II degree looseness according the data from literature was established. A load of 100 N was applied vertically or at 45?to vertical. The stress in bone implant interface, dentin and periodontal ligament was measured and analysed with Super sap(1991 edition) FEA software in a IBM PC(PIII 550).Results: The mobility of the tooth was decreased by endodontic endosseous implant with periodontal compromises, and lower stress was observed at the alveolar crest and periodontal membrane after implantation with inclined load. High stress concentration on the implant/bone interface was produced below the canal orifice and implant apex, and at root apex within dentin.Conclusion: Endodontic endosseous implant can be used to stabilize the tooth with periodontal compromises, and to improve the stress distribution around the root.