Preparation and Quality Control of Anti-inflammatory Dental Ulcer Film
- VernacularTitle:抗口腔溃疡炎膜剂的制备及质量控制
- Author:
Xin HE
- Publication Type:Journal Article
- Keywords:
Anti-inflammatory dental ulcer film;
Indirubin;
Preparation;
Quality Control;
HPLC method
- From:
China Pharmacy
2005;0(17):-
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVE: To prepare anti-inflammatory dental ulcer film and establish its quality standard. METHODS: Drug-containing mortar and blank mortar were prepared to prepare compound film agent. HPLC was used to the quantitative analysis of indirubin. RESULTS: The preparation had well appearance and its detection of index was up to the standard stated in Chinese Pharmacopeia. The linear range of indirubin was 0.8~6.4 ?g?mL-1 (r=0.999 8) with an average recovery rate of 100.65% (RSD=1.07%,n=6). CONCLUSION: The formula of preparation is reasonable, the preparation method is simple and applicable and determination method is accurate and reliable.