Determination of the Dissolution of Lovastatin Tablets
- VernacularTitle:洛伐他汀片溶出度测定
- Author:
Yanxia GAO
;
Xiru ZHANG
;
Jing ZHANG
;
Jianguo JIANG
- Publication Type:Journal Article
- Keywords:
Lovastatin;
Tablets;
Dissolution;
HPLC
- From:
China Pharmacy
2007;0(28):-
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVE:To establish a method for determination of the dissolution of lovastatin tablets and to investigate the dissolution of it from different manufactures.METHODS:HPLC was employed for content determination with Alltima C18 chromatographic column,and the mobile phase consisted of acetonitrile-0.01% phosphoric acid(60∶40)with the detective wavelength set at 238 nm.The dissolution was determined by paddle method with 2% sodium lauryl sulphate-phosphate buffered solution(pH 7.0)as medium at a rotation speed of 50 r?min-1,and the sampling time was 30 min.The dissolution rates of 12 batches of samples from 6 manufacturers were determined.RESULTS:The linear range of lovastatin was 4.88~195.2 ?g?mL-1(r=0.999 9)and its average recovery rate was 97.7%(RSD=1.3%,n=9).Of the 12 batches of samples,3 batches from 2 manufacturers had dissolution rates of less than 80%,and the other batches stood at 80%~101%.CONCLUSION:The method is accurate,reproducible and simple,and it is effective in the quality control of lovastatin tablets.