Determination of Plasma Concentration of Sirolimus by SPE-HPLC
- VernacularTitle:固相萃取-HPLC法测定西罗莫司的血药浓度及其临床应用研究
- Author:
Shuxia LI
;
Bin REN
;
Changxi WANG
;
Xiaodan HONG
- Publication Type:Journal Article
- Keywords:
Sirolimus;
Solid phase extraction;
HPLC;
Blood concentration
- From:
China Pharmacy
2005;0(20):-
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVE: To establish a SPE-HPLC method to determine the whole blood concentration of sirolimus.METHODS: The blood sample was treated on Waters OASIS SPE column in which a Supelcosil LC-18DB chromatographic column(250 mm?4.6 mm,5 ?m) was adopted and the temperature was set at 50 ℃.The mobile phase was a mixture of methanol and water(75∶25) at a flow rate of 1.5 mL?min-1.The UV detector was operated at 276 nm.RESULTS: The assay procedure was shown to produce linear calibration curves over the range 1.25~70 ng?mL-1 of sirolimus in blood(r=0.999 7).The limit of detection was 0.5 ng?mL-1.Within the range,the average recovery rate was(101.7?2.7)% and the extraction recovery rate was≥82.8%.The coefficients of variation within a day and between days did not exceed 4.0% and 5.4%,respectively.CONCLUSION: This method is found to be easy,convenient and precise for fast monitoring of plasma concentration of sirolimus.