Content Determination of Fe in Iron Dextran Preparations by UV-VIS
- VernacularTitle:紫外-可见分光光度法测定右旋糖酐铁制剂中铁的含量
- Author:
Yun ZHAO
;
Hong YE
- Publication Type:Journal Article
- Keywords:
UV-VIS;
Iron dextran;
Preparations;
Content determination
- From:
China Pharmacy
2001;0(10):-
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVE:To establish the ultraviolet visible spectrophotometry(UV-VIS)for the determination of Fe content in iron dextran preparations.METHODS:Under the acidic condition,Fe~(3+)was dissociated from iron dextran solution by heating,then Fe~(3+)was deoxidized into Fe~(2+)by hydroxylamine hydrochloride,and red Fe~(2+)-orthophenanthroline complex was formed through combination with o-phenanthroline.The content of the Fe~(2+)-orthophenanthroline complex was determined by UV-VIS at a wavelength of 510 nm.RESULTS:The linear range of Fe~(2+)was 0.5~4.0?g?mL~(-1)(r=0.999 9). The average recoveries of two preparations(tablets and injection)of iron dextran were 99.8%(RSD=0.52%)and 99.7% (RSD=0.44%),respectively.CONCLUSION:The UV-VIS method is simple,accurate in results and applicable for the determination of iron dextran preparations.