Determination of Phenacetin and Paracetamol in Rat Liver Microsomal Incubation System with HPLC/MS/MS
- VernacularTitle:HPLC/MS/MS法测定大鼠肝微粒体系统中非那西丁及其代谢物的浓度
- Author:
Yan LIU
;
Yubo HAN
;
Yuhong TENG
;
Jing XU
;
Zhimin DU
- Publication Type:Journal Article
- Keywords:
HPLC/MS/MS;
Phenacetin;
Paracetamol;
Rat;
Liver microsomal;
Incubation system
- From:
China Pharmacy
2001;0(07):-
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVE: To develop a method of HPLC/MS/MS to determine phenacetin and paracetamol in rat liver microsomal incubation system. METHODS: Samples were separated on XTerra MS C18 column, different ratios of methanol- 0.1% formic acid were used as the gradient eluent, and the flow rate was 0.2mL?min-1. The electrospray ion-quadrupole mass spectrometry and multiple reaction monitor were adopted to detect the concentration of phenacetin and paracetamol. RESULTS: The calibration curves were linear in the ranges of 45~9 000ng?mL-1(r=0.999 8)and 15.2~1 520ng?mL-1(r=0.999 6) for phenacetin and paracetamol respectively; The lowest limits of assay were 9ng?mL-1 and 10ng?mL-1.The average recoveries at three concentrations of phenacetin were (96.2?2.3)%~(98.3?2.4)% and those of paracetamol were (99.6?2.1)%~(100.2?2.6)%; RSD of the intra-day and inter-day were less than 5%. CONCLUSION: The method is rapid, sensitive and suitable for determination of phenacetin and paracetamol in rat liver microsomal incubation system.