Value of using CT software technic to prevent the postoperative syndrome in functional endoscopic sinus surgery
- VernacularTitle:功能性鼻窦内镜手术应用CT软件技术在预防手术并发症中的临床意义
- Author:
Li SHEN
;
Qingshui LI
;
Guoqi YUAN
;
Qizhao LIAO
;
Haiming LIU
- Publication Type:Journal Article
- Keywords:
Endoscopic sinus surgery;
Tomography, X-ray computer
- From:
Chinese Journal of Postgraduates of Medicine
2006;0(18):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective To evaluate the guiding effect of CT software to reduce the postoperative syndrome and surgery risk in patients with sinus disease performed the functional endoscopic sinus surgery (FESS). Methods Fifty patients of accessory sinus disease were scanned by spinal CT, and then three dimensions reconstruction made in workstation. Under center of ethmoid sinus ,the five groups of anatomy data measured were obtained , used to guide surgery and contrasted with result of no used to guide surgery in 68 patients in FESS. The data were performed the statistical management and compared with results of FESS. Results Under guided by five groups of anatomy data measured ,the postoperative syndrome was reduced by 16.0 percent; the curative effect went up by 15.0 percent; the pay for hospital was reduced 31.0 percent and the recurrence rate was reduced 8.6 percent. Conclusion Used the technic in FESS, the surgery risk, the recurrence rate and pay for hospital are reduced, but the curative effect go up. The technic is much adapt to be used in village and towns hospital where there aren′t navigation equipment.