Application of Quality Control Graphs in Blood Concentration Monitoring of Tacrolimus
- VernacularTitle:他克莫司血药浓度监测中质控图的应用
- Author:
Xin WANG
;
Jinping ZHANG
;
Lili HUANG
- Publication Type:Journal Article
- Keywords:
Tacrolimus;
Therapeutic drug monitoring;
Indoor quality control;
Enzyme-linked immunosorbent assay
- From:
China Pharmacy
2001;0(08):-
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVE:To increase the accuracy of blood concentration monitoring results of tacrolimus.METHODS:Blood concentrations of tacrolimus(60points for high and low quality control,respectively)were determined by enzyme-linked immunosorbent assay and the quality control graphs were drawn.The whole monitoring course underwent both prospective and retrospective quality control.RESULTS:The quality control monitoring results could be evaluated from the quality control graphs.CONCLUSION:Quality control can effectively increase the accuracy of blood concentration monitoring results of tacrolimus,which can also prevent and rectify systemic error.