Concentration Determination of Floxuridine in Serum and Organs of Mice by RP-HPLC
	    		
		   		
	    	
    	
    	
   		
        
        	
        		- VernacularTitle:反相高效液相色谱法测定小鼠血清及脏器中氟尿苷的浓度
- Author:
	        		
		        		
		        		
			        		Jiafang LIAN
			        		
			        		;
		        		
		        		
		        		
			        		Sanqi ZHANG
			        		
			        		;
		        		
		        		
		        		
			        		Yi GU
			        		
			        		;
		        		
		        		
		        		
			        		Kunquan FANG
			        		
			        		;
		        		
		        		
		        		
			        		Miaomiao XI
			        		
			        		;
		        		
		        		
		        		
			        		Li WANG
			        		
			        		
		        		
		        		
		        		
 
			        		
			        		
		        		 
- Publication Type:Journal Article
- Keywords:
        			
	        			
	        				
	        				
			        		
				        		RP-HPLC;
			        		
			        		
			        		
				        		Floxuridine;
			        		
			        		
			        		
				        		Serum;
			        		
			        		
			        		
				        		Tissue homogenate
			        		
			        		
	        			
        			
        		
- From:
	            		
	            			China Pharmacy
	            		
	            		 2005;0(23):-
	            	
            	
- CountryChina
- Language:Chinese
- 
		        	Abstract:
			       	
			       		
				        
				        	OBJECTIVE: To establish RP-HPLC method for the fast determination of floxuridinein in serum and homogenate of some of the organs of mice. METHODS: The determination was performed on C18 chromatographic column with its mobile phase consisted of phosphate buffer(pH= 7.4) - methanol(95∶5) and with its detection wavelength at 268nm. RESULTS: Linear detection concentration ranges of floxuridinein were all at 15~240?g/ml. The minimum detection concentration was 3?g/mL(S/N≥3). The average extraction recovery was above 95%. The average recovery ranged from 91%to 112%. Both the intra-day and inter-day precisions were less than 10%. CONCLUSION: The method is simple, rapid, reliable and economical, and it can be used for the determination of serum floxuridinein concentration and the study of its body distribution in animals.