Intraoperative paravalvular leakage after sutureless aortic valve replacement corrected with secondary balloon dilatation: A case report.
10.17085/apm.2016.11.2.186
- Author:
Bo Ra LEE
1
;
Junheum JANG
;
Shin Young LEE
;
Jong Wook SONG
Author Information
1. Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, Korea. sjw72331@yuhs.ac
- Publication Type:Case Report
- Keywords:
Paravalvular leakage;
Sutureless aortic valve replacement;
Transesophageal echocardiography
- MeSH:
Aged;
Alloys;
Aortic Valve Stenosis;
Aortic Valve*;
Cardiopulmonary Bypass;
Dilatation*;
Echocardiography, Transesophageal;
Female;
Humans;
Stents;
Water;
Weaning
- From:Anesthesia and Pain Medicine
2016;11(2):186-189
- CountryRepublic of Korea
- Language:English
-
Abstract:
Sutureless aortic valve replacement was performed in a 72-year-old female patient with severe aortic stenosis who had undergone coronary revascularization and pacemaker implantation. After valve excision, decalcification was deliberately incompletely performed at the commissure of the left- and non-coronary cusp to obtain a regular and circular annular margin. After implantation of the stented valve, no paravalvular leakage was noted on water irrigation testing. Upon weaning from cardiopulmonary bypass, a moderate degree of paravalvular leakage was observed by transesophageal echocardiography at the junction of the left- and non-coronary cusp. Instead of removing the valve and performing more complete decalcification to implant a larger valve, secondary balloon dilatation and warm sterile water irrigation were performed to allow further expansion and fixing of the metal alloy stent around the aortic wall to minimize the duration of aortic cross-clamp. No paravalvular leakage was observed thereafter and the patient was discharged without any complications.