Osteoporosis prediction from the mandible using cone-beam computed tomography.
10.5624/isd.2014.44.4.263
- Author:
Imad BARNGKGEI
1
;
Iyad AL HAFFAR
;
Razan KHATTAB
Author Information
1. Department of Oral Medicine, Faculty of Dentistry, Damascus University, Damascus, Syria. imadbarn@gmail.com
- Publication Type:Original Article
- Keywords:
Bone Density;
Cone-Beam Computed Tomography;
DXA Scan;
Osteoporosis
- MeSH:
Absorptiometry, Photon;
Bone Density;
Cone-Beam Computed Tomography*;
Diagnosis;
Female;
Femur Neck;
Hip;
Humans;
Logistic Models;
Lumbar Vertebrae;
Mandible*;
Osteoporosis*;
Sensitivity and Specificity
- From:Imaging Science in Dentistry
2014;44(4):263-271
- CountryRepublic of Korea
- Language:English
-
Abstract:
PURPOSE: This study aimed to evaluate the use of dental cone-beam computed tomography (CBCT) in the diagnosis of osteoporosis among menopausal and postmenopausal women by using only a CBCT viewer program. MATERIALS AND METHODS: Thirty-eight menopausal and postmenopausal women who underwent dual-energy X-ray absorptiometry (DXA) examination for hip and lumbar vertebrae were scanned using CBCT (field of view: 13 cmx15 cm; voxel size: 0.25 mm). Slices from the body of the mandible as well as the ramus were selected and some CBCT-derived variables, such as radiographic density (RD) as gray values, were calculated as gray values. Pearson's correlation, one-way analysis of variance (ANOVA), and accuracy (sensitivity and specificity) evaluation based on linear and logistic regression were performed to choose the variable that best correlated with the lumbar and femoral neck T-scores. RESULTS: RD of the whole bone area of the mandible was the variable that best correlated with and predicted both the femoral neck and the lumbar vertebrae T-scores; further, Pearson's correlation coefficients were 0.5/0.6 (p value=0.037/0.009). The sensitivity, specificity, and accuracy based on the logistic regression were 50%, 88.9%, and 78.4%, respectively, for the femoral neck, and 46.2%, 91.3%, and 75%, respectively, for the lumbar vertebrae. CONCLUSION: Lumbar vertebrae and femoral neck osteoporosis can be predicted with high accuracy from the RD value of the body of the mandible by using a CBCT viewer program.