Determination of Nitrochlodipine in Rabbit Plasma With RP-HPLC
- VernacularTitle:反相高效液相色谱法测定兔血浆中硝洛地平浓度
- Author:
Xiaohong LIU
;
Jian GE
;
Qiang XUE
- Publication Type:Journal Article
- Keywords:
nitrochlodipine;
RP-HPLC;
orthogonal design
- From:
China Pharmacy
1991;0(05):-
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVE:To establish a RP-HPLC method for the determination of nitrochlodipine in rabbit plasma.METH-ODS:Chromatographic conditions and extractive conditions were optimized with orthogonal design,internal standard:felodipine,solid phase extract column:C18,column size:NOVA-PackC18(4.6mm?250mm),detection wavelength:237nm.RESULTS: The optimal chromatographic conditions were:mobile phase acetonitrile-water(55∶45),flow rate 1.0ml/min,column temperature 45℃.The extraction conditions were A1 B1 C3.The calibration curve was linear within the range of 6.25~400?g/L(r=0.9 996) and the minimum limit of detection was 2.5?g/L.The average RSD of within-day ranged from 3.81% to 5.58% and that of day-to-day from 4.60% to 8.76%.The average recovery ranged from 100.7% to 101.8%.CONCLUS-ION:The method is simple,rapid,highly accurate and precise.It can be used for the quantitative determination of nitrochlodipine in plasma.