Abstract:
OBJECTIVE:To build up a method of determining the concentration of midazolam in plasma by RPHPLC-UV detection.METHODS:The separation was carried out by a reversed-phase Hypersil ODS column(250mm?4.0mm,5?m) with a mobile phase consisting of methanol-acetonitrile-0.02mol/L potassium phosphate buffer(pH 7.4) (65∶25∶10,V/V).Mida_zolam was extracted from alkalinizing plasma and soluted in the mobile phase then detected at 221nm.RESULTS:The calibration curve had the fine linearity in the concentration range 50~1 600ng/ml(r=0.9 999).The detection limit was 2ng/ml.The absolute recovery was 90.8%~95.4%,the relative recovery was 99.3%~101.3%.The within-day and between-day precision(CV%) was 1.94%~5.16%,3.00%~6.39% respectively.CONCLUSION:The method is simple,stable and highly sensitive and could meet with the research of clinical pharmacokinetics.