Hemodynamic changese during the procedure or double cardiac valve replacement.
- VernacularTitle:心脏双瓣置换术麻醉期间血流动力学变化
- Author:
Xiaoping YE
;
Guangjun XIAO
;
Weixian ZHAO
- Publication Type:Journal Article
- Keywords:
Hemodynamic Cardiac valve replace ment Cardiovascular anesthesia
- From:
Chinese Journal of Anesthesiology
1994;0(04):-
- CountryChina
- Language:Chinese
-
Abstract:
The hemodynamics of 49 scheduled patients during anesthesia and opration for mitral and aortic valve replacement were studied with the insertion of SwanGanz catheter and by the method of thermodilution technics.Pre-anesthesia CI and LVWI were in the nor mal range with abnormal MPAP, PCWP, PTRI and RVWI.Increase of RAP and decrease in MPA,PCWP, MAP, CI, LVWI and RVWI were observed during induction of anesthesia. The hemodynamic parameters returned to or exceded the pre-anesthesia values after trachcal intubation and sternotomy. The CI, MAP, MPAP, PCWP, LVWI and RVWI decreased signifi- cantly after insertion of aorta and vena cava catheter. The reduction of MPAP, P(IWP,PTRI and RVWI post-cardiopulmonary bypass (CPB) were significant and persistent with no change of PVRI.The lower MAP,SVRI and deterioration of cardiac performance post-CPB indicate that the administeration of positive inotropir agents and restoration of hematocrit are nec essary as early as possible.