The Use of the Contrast Medium in Abdomen CT Scanning
- VernacularTitle:腹部CT扫描中造影剂的应用
- Author:
Dan HAN
- Publication Type:Journal Article
- Keywords:
Abdoomen CT scanning;
Urografin;
Contrast;
Artifect
- From:
Journal of Kunming Medical University
1988;0(03):-
- CountryChina
- Language:Chinese
-
Abstract:
The expxprience of 8 thousand cases using contrast medium in abdomen CT scanning were reported.The results showed that it was more suitable for selecting 76% Urografin.The best oral concentration was 1.5%.In abdomen scanning intramuscular injection 654-2 conventionally could improve the image quality.The rectum and sigmoid region scanning should use tee contraast medium through the anus.Vein injection rapidly(bolus)was a best vein contrast method.When visualing badly after bolus or needing observe vessels of contin- uous several sections,continuous bolus method was used.while delay scanning was often used in defining nature of angioma.