Application of a guide-wire shaping during subclavian vein catheterization
10.3760/cma.j.issn.1674-635X.2017.02.011
- VernacularTitle:导丝塑型在锁骨下静脉置管中的应用
- Author:
Xingwei SUN
;
Xuming BAI
;
Long CHENG
;
Xingshi GU
;
Qiang YUAN
;
Jian JING
;
Jian ZHANG
;
Yong JIN
- Keywords:
Catheters;
Subclavian vein;
Internal jugular vein;
Ectopic
- From:
Chinese Journal of Clinical Nutrition
2017;25(2):124-126
- CountryChina
- Language:Chinese
-
Abstract:
Objective To explore the clinical value of guide-wire shaping in subclavian vein catheter-ization.Methods Totally 400 patients requiring right subclavian vein catheterization were equally divided into two groups according to the clinic date: intervention group ( with guide-wire shaping , n =200 ) and control group (without guide-wire shaping, n=200).The catheterization was carried out by the same doctor .The rates of ectopic wire were compared between the two groups .Results The overall success rate of catheteriza-tion was 98.25%(393/400) [98.5% (197/200) in intervention group and 98.0% (196/200) in control group, P=0.500].The incidence of catheter displacement was 1.02%(2/197) in intervention group, which was significantly lower than that [7.14% (14/196)] in control group (P=0.002).Conclusion As a sim-ple procedure , guide-wire shaping can effectively prevent catheter displacement during catheterization .