Therapeutic effects of ultrasound biomicroscopy assisted intraocular lens suspension surgery with one loop suturing for residual lens capsule aphakia
10.13389/j.cnki.rao.2017.0046
- VernacularTitle:超声生物显微镜辅助折叠人工晶状体单襻悬吊术治疗残留部分囊膜无晶状体眼患者临床疗效分析
- Author:
Ruifeng SU
;
Xiaobo TAN
;
Litao GUO
;
Weili DONG
- Keywords:
ultrasound biomicroscopy;
intraocular lens;
suspension with one loop;
surturing fixation
- From:
Recent Advances in Ophthalmology
2017;37(2):175-178
- CountryChina
- Language:Chinese
-
Abstract:
Objective To evaluate the therapeutic effects of ultrasound biomicroscopy (UBM) assisted intraocular lens suspension surgery with one loop suturing for residual lens capsule aphakia.Methods Fifty aphakia patients (50 eyes) with residual lens capsular equal or greater than 180 degrees were chosen.The patients were randomly divided into 2 groups and underwent intraocular lens suspension surgery with one loop suturing:Trial group (25 cases,25 eyes) selected suture site according to the preoperative UBM results,and control group (25 cases,25 eyes) selected the suture site according to the clinical experience.The uncorrected visual acuity (UCVA),astigmatism at preoperative and postoperative 1 week,1 month and 3 months were observed,the eccentric and tilt value of the lens were calculated by UBM measurement at 3 month after operation,and the postoperative complications of the two groups were observed.Results UCVA at each time point after operation were higher than that before operation,and gradually increased with time.There was no significant difference between the two groups at 1 week before and after the operation of UCVA (P > 0.05).At 1 month and 3 months after operation,UCVA in trial group were significantly higher than those of control group (all P < 0.05).The astigmatism value at 1 week after operation in two groups was higher than that before operation and gradually decreased with time.The astigmatism value in trial group at 1 month and 3 months after operation had no significant difference with that of preoperative (P > 0.05),while the astigmatism value in control group increased (all P < 0.05).The astigmatism values had no significant difference between the two groups before and 1 week after operation (all P >0.05),which were significantly lower in trial group at 1 month and 3 months after operation (all P < 0.05).Three months after surgery,the proportion of lens accurately implanted in the ciliary sulcus was significantly higher than control group (P < 0.01),the eccentric and tilt values of the lens in trial group were significantly less than control group (P < 0.01).No serious complication was observed in all patients.Conclusion UBM assisted intraocular lens suspension surgery with one loop suturing can significantly improve the postoperative visual quality,safety and lens stability,which can be used as a routine preoperative examination of intraocular lens suspension surgery.In addition,UBM provides an alternative method for the calculation of the eccentricity and tile value of the intraocular lens after the implantation of the intraocular lens.