Efficacy analysis on arterial catheter stents for pulmonary atresia with intact ventricular septum in newborns
10.3760/cma.j.issn.2095-428X.2016.23.009
- VernacularTitle:动脉导管内支架治疗新生儿室间隔完整型肺动脉闭锁的疗效分析
- Author:
Zhongjian CHEN
;
Fang LI
;
Bo ZHAI
;
Zhenliang CHEN
;
Penggao WANG
;
Lei SHI
;
Fang YANG
;
Xiangyang DONG
;
Wenbo YU
- Keywords:
Pulmonary atresia;
Pulmonary shunt;
Infant,newborn;
Artery catheter;
Stent
- From:
Chinese Journal of Applied Clinical Pediatrics
2016;31(23):1795-1798
- CountryChina
- Language:Chinese
-
Abstract:
Objective To compare the efficacy of arterial stenting with that of traditional B -T shunt for neo-natal pulmonary atresia with intact ventricular septum.Methods Twenty -six cases of neonatal pulmonary atresia with intact ventricular septum were treated at Children′s Hospital of Zhengzhou from December 2005 to December 201 5,aged 3 to 23 days[(8.20 ±4.80)days],and weighted 2.80 -3.88 (3.41 ±0.27)kg.Accompanied with pulmonary hypo-plasia,all these patients were combined with PDA and ASD or PFO.Before operation,the peripheral oxygen saturation was kept in 61 % -75%,averaged at 67%.Among them,1 2 cases underwent arterial catheter stenting,and 1 4 cases re-ceived B -T shunt (including modified B -T shunt and central shunt)ductus ligation.After operation,the oxygen satu-ration in these children was observed,and they were examined by echocardiography and true lateral chest X -ray,blood flow situations in stents and shunts were assessed,and follow -up examinations were conducted in 1 ,3,6 and 1 2 months postoperatively.Results Stents were successfully inserted into these 1 2 cases.After traditional pulmonary shunt,pa-tients′peripheral oxygen saturation was (82.73 ±5.59)%,compared with that of patients after arterial catheter sten-ting (86.1 8 ±3.1 9)%,there was significant difference(t =1 0.71 ,P <0.05).In pulmonary shunt group,2 cases died,1 case died of postoperative heart failure,and the other case was complicated with pulmonary infection and died of respiratory failure;in catheter stent group,1 case was complicated with postoperative supraventricular tachycardia and recovered after drug intervention.For the follow -up examinations 1 ,3,6 and 1 2 months after the operation,1 case of B -T shunt in pulmonary shunt group was improved by central shunt due to slow blood flow,less shunt volume,and ox-ygen saturation decreased to 69%.For the catheter stent group,1 case was improved by stent balloon dilatation due to declined peripheral oxygen saturation 2 months postoperatively,and after the operation,transcutaneous oxygen saturation was improved.No patients died in the catheter stent group.Conclusions In traditional B -T shunts,the operation is extensive,and complications are common,and the recovery turns slowly.Arterial catheter stenting can be used as the preferred method of treatment for one -stage surgical pulmonary atresia with intact ventricular septum to reduce the weakness feasibly and effectively.