Reproducibility of Anal Manometric Measurement.
- Author:
Kwan Woo SUN
;
Moo Kyung SEONG
- Publication Type:Original Article
- Keywords:
Anorectal manometry;
Pressure profile;
Reproducibility
- MeSH:
Anal Canal;
Capillaries;
Cough;
Humans;
Male;
Manometry;
Perfusion
- From:Journal of the Korean Society of Coloproctology
1998;14(3):483-492
- CountryRepublic of Korea
- Language:Korean
-
Abstract:
PURPOSE: Anorectal manometry has become a routine investigation for the evaluation of patients with anorectal disorders. However, the interpretation of such studies is confounded by the fact that controversial data are reported with regard to the same events. The aim of this study was to measure the reproducibility of the pressure profiles of anorectal manometry in healthy controls for standardization of their measurements. METHODS: Manometric study was performed on different days with 7 days interval in 22 male healthy subjects with the use of a pneumohydraulic capillary perfusion system. RESULTS: For resting pressures with rapid pull-through (RPT) technique, maximum pressure revealed 43.58, 19.8% and mean pressure, 16.02, 14.6% in the order of reproducibility coefficient and coefficient of variation. For resting pressures with stationary pull-through (SPT) technique, maximum pressure; 17.22, 12.2% and mean pressure; 14.66, 26.4%, respectively. For squeezing pressures with RPT technique, maximum pressure; 53.37, 14.3% and mean pressure; 66.32, 23.6%. For squeezing pressures with SPT technique, maximum pressure; 72.80, 11.9%, mean pressure; 93.10, 30.5% and coughing pressure; 69.42, 15.8%, respectively, For anal canal length (ACL) with RPT technique, at resting state; 7.10, 7.9% and at squeezing state; 14.55, 13.7%, respectively. For high pressure zone (HPZ) with RPT technique, at resting state; 6.68, 16.3% and at squeezing state; 11.06, 23.5%. For HPZ with SPT technique, at resting state; 11.28, 25.4% and at squeezing state; 10.04, 17.5%, respectively. For radial asymmetry (RA) with RPT technique, at resting state; 13.76, 42.3% and at squeezing state; 7.86, 22.9%. For RA with SPT technique, at resting state; 24.6, 58.6% and at squeezing state; 14.28, 46.7%, respectively. CONCLUSION: Measurements of resting and squeezing pressure are more reproducible by SPT technique, in which technique it seems that maximum value is more preferred as a representative value. ACL and HPZ are may well measured on resting pressure with SPT technique. Radial asymmetry shows the best reproducibility on squeezing pressure with RPT.