Determination of All-trans-retinyl Palmitate in Multivitamin Preparations by HPLC
- VernacularTitle:HPLC法测定复合维生素制剂中全反式维生素A棕榈酸酯的含量
- Author:
Yanzhong DIAO
;
Weijun WU
;
Jiang CHANG
;
Yanfeng CAO
- Keywords:
Multivitamin preparations;
All-trans-retinyl palmitate;
Content determination;
HPLC
- From:
China Pharmacist
2017;20(2):377-379
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To determine the content of all-trans-retinyl palmitate in multivitamin preparations. Methods: HPLC was used and the chromatographic column was Apollo Silica (250 mm × 4. 6 mm, 5 μm). The mobile phase consisted of hexane-isopro-panol (999. 5:0. 5) and the column temperature was 30 ℃. The detection wavelength was 325 nm and the flow rate was 1. 0 ml· min-1 . The injection volume was 100 μl. Results:The calibration curve of all-trans-retinyl palmitate was linear within the concentra-tion range of 0. 2260-0. 6780 IU·ml-1(0. 1243-0. 3729 μg·ml-1, r=0. 9999). The average recovery was 99. 86%, and RSD was 0. 64%(n=9). Conclusion:The method is simple,accurate,sensitive,reproducible and universal, which can be used for the con-tent determination of all-trans-retinyl palmitate in multivitamin preparations.