Clinical observation of the effect of breast removal of polyacrylamide hydrogel by areola medial semicircular incision
10.3760/cma.j.issn.1008-6706.2016.21.013
- VernacularTitle:经乳晕内侧半圆切口入路行乳房聚丙烯酰胺水凝胶取出术的临床观察
- Author:
Shengsheng PAN
;
Jinjun ZHAO
;
Zhenwen PAN
;
Binting NI
- Publication Type:Journal Article
- Keywords:
Polypropylene;
Breast implants;
Device reval;
Surgical procedures,Minimally invasiue
- From:
Chinese Journal of Primary Medicine and Pharmacy
2016;23(21):3252-3255
- CountryChina
- Language:Chinese
-
Abstract:
Objective To learn the effect of breast removal of polyacrylamide hydrogel by areola incision;and to provide an effective method for removal of polyacrylamide hydrogel.Methods According to the accepted operation,45 cases with breast polyacrylamide hydrogel were divided into 25 cases of observation group and 20 cases of control group.The observation group was treated with areola medial semicircular incision breast removal of polyac-rylamide hydrogel,and the control group was treated with areola small incision suction to remove polyacrylamide hydrogel.The operative time,intraoperative blood loss,postoperative drainage tube extraction time,postoperative 7d breast shape and perioperative complications of the two groups were observed;postoperative follow -up was performed to evaluate the effect of surgery.Results The operation time of the observation group (190.2 ±36.1)min was longer than (119.5 ±44.0)min of the control group,the difference was statistically significant between the two groups (t =5.924,P <0.05);the intraoperative blood loss of the observation group (250.4 ±23.9)mL was higher than (89.7 ± 30.4)mL of the control group,the difference was statistically significant (t =19.865,P <0.05 ).The difference between postoperative 7d breast normal morphology rates of the two groups was not statistically significant (χ2 =2.571,P >0.05);the postoperative drainage tube extraction time of the observation group (3.7 ±0.5)d was more than (2.3 ±0.3)d of the control group,the difference was statistically significant (t =11.021,P <0.05 ).The complication rate of the observation group was 12.0%(3 /25),which of the control group was 10.0%(2 /20),the difference was not statistically significant (χ2 =0.045,P >0.05).All cases of the two groups were followed up;the mean follow -up time was (6.7 ±2.1)months.The good rate of surgery of the observation group was 92.0 % (23 /25),which of the control group was 70.0%(14 /20),the observation group was higher than the control group (χ2 =5.718,P <0.05).Conclusion For patients with complications after polyacrylamide hydrogel injection for augmentation mammoplasty;the breast polyacrylamide hydrogel removal surgery by areola medial semicircular incision is recommen-ded as the preferred.