Simultaneous Determination of Fluoxertine and Olanzapine in Capsules by HPLC
- VernacularTitle:HPLC同时测定复方氟西汀奥氮平胶囊中药物含量
- Author:
Rong DU
;
Li REN
;
Song FANG
- Publication Type:Journal Article
- Keywords:
Fluoxertine;
Olanzapine;
Determination;
HPLC
- From:
China Pharmacist
2016;19(10):1975-1977
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To establish a method for the simultaneous determination of fluoxertine and olanzapine in capsules by re-versed-phase high performance liquid chromatography ( RP-HPLC) . Methods:The successful separation of fluoxertine and olanzapine was achieved on a Phenomenex C18 column (250 mm × 4. 6 mm, 5 μm) with 10 mmol·L-1 potassium dihydrogen phosphate buffer (pH 4. 0)-acetonitrile-methanol (55 ∶40 ∶5, v/v/v) as the mobile phase. The flow rate was 1. 0 ml·min-1, the detection wave-length was 227 nm, the column temperature was 30℃, and the injection volume was 20 μl. Results:Fluoxertine could be well separa-ted from olanzapine under the chromatographic conditions. The linearity between the peak areas and the concentrations was observed within the range of 5. 0-80. 0 mg·L-1(r=0. 999 9) for fluoxertine and 1. 2-19. 2 mg·L-1(r=0. 999 9) for olanzapine. The mean recovery of fluoxertine and olanzapine was 99. 9%(RSD=0. 94%, n=9) and 100. 2%(RSD=2. 08%, n=9), respectively. Con-clusion:The method is simple, sensitive and accurate, and it can be applied in the content determination of fluoxertine and olanzapine in capsules.