Volumetric modulated arc therapy for nasopharyngeal carcinoma patients with poor compliance: setup error and expansion margin of target volume
	    		
		   		
		   			 
		   		
	    	
    	 
    	10.3760/cma.j.issn.1004-4221.2016.09.015
   		
        
        	
        		- VernacularTitle:配合度较差鼻咽癌患者VMAT摆位误差及靶区外扩距离的研究
- Author:
	        		
		        		
		        		
			        		Jie CHEN
			        		
			        		;
		        		
		        		
		        		
			        		Wenxue ZHANG
			        		
			        		;
		        		
		        		
		        		
			        		Keqiang WANG
			        		
			        		;
		        		
		        		
		        		
			        		Zhichao GUO
			        		
			        		;
		        		
		        		
		        		
			        		Jun WU
			        		
			        		;
		        		
		        		
		        		
			        		Yongzhen CAO
			        		
			        		;
		        		
		        		
		        		
			        		Zhonghong LYU
			        		
			        		
		        		
		        		
		        		
 
			        		
			        		
		        		 
- Publication Type:Journal Article
- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Nasopharyngeal neoplasmsm/volumetric modulated arc therapy;
			        		
			        		
			        		
				        		Setup error;
			        		
			        		
			        		
				        		Target volume margin;
			        		
			        		
			        		
				        		Dose distribution
			        		
			        		
	        			
        			
        		
- From:
	            		
	            			Chinese Journal of Radiation Oncology
	            		
	            		 2016;25(9):971-974
	            	
            	
- CountryChina
- Language:Chinese
- 
		        	Abstract:
			       	
			       		
				        
				        	Objective To investigate the setup error for nasopharyngeal carcinoma (NPC) patients with poor compliance using kV cone-beam computed tomography,and to calculate the expansion margin from the clinical target volume (CTV) to planning target volume (PTV).Methods In 45 NPC patients from 2013 to 2015,the setup error,95% confidence interval (CI)-1 for random error,and PTV-1 value were calculated.Moreover,in 16 NPC patients with poor compliance based on five verifications (random error not within 95% CI-1),the setup error,95% CI-2 for random error,and PTV-2 value were calculated.For the 16 special patients,PTV-1 and PTV-1 combined with PTV-2 were used to develop the plan-1 and plan-2,respectively.The dosimetric difference between plan-1 and plan-2 was evaluated.Results Both PTV-1 and PTV-2 had the largest expansion margin in the y direction.The CTV of plan-1 could not meet the requirement of the prescription dose after the setup error was introduced.Compared with plan-1,the V95% and D95 values for the CTV of plan-2 were increased by 6.26% and 4.43%,respectively.The D01 value was significantly larger in plan-2 than in plan-1 (P=0.005),which,however,met the clinical requirement.Conclusions In patients with poor compliance,the dose to target volume can be effectively elevated and the normal tissue can be spared from damage when PTV-1 combined with PTV-2 is selected as expansion margin.