The preliminary application of intraoperative optical coherence tomography in vitreous retinal surgery
10.3760/cma.j.issn.1005-1015.2016.05.008
- VernacularTitle:手术中光相干断层扫描在玻璃体视网膜手术中应用的初步观察报告
- Author:
Jiwei TAO
;
Qihua WANG
;
Mengqi CHU
;
Lingya SU
;
Dong FANG
;
Lijun SHEN
- Publication Type:Journal Article
- Keywords:
Vitreoretinal surgery/instrumentation;
Tomography,optical coherence
- From:
Chinese Journal of Ocular Fundus Diseases
2016;32(5):491-494
- CountryChina
- Language:Chinese
-
Abstract:
Objective To observe the preliminary application of intraoperative optical coherence tomography (iOCT) in vitreous retinal surgery and the influencing factors of the imaging quality.Methods A retrospective case study.A total of 132 subjects were chosen in June 2015 and April 2016 in our hospital.All the subjects were taken vitreous retinal surgery and iOCT scanning.The patients included 46 males and 86 females,with an average age of 61.7 years.111 cases had macular diseases and 21 cases had vitreous hemorrhage.Cases are divided into high myopia and non high myopia group according to ocular axial length (AL),28 eyes in high myopia group (AL≥26 mm),104 eyes in non-high myopia (AL<26 mm).The scanning time,image quality and eye conditions were observed during the operation.The discordance between surgeon microscope visualization of the pathology and the findings of the iOCT and the postoperative adverse reactions were also observed.Results The iOCT images were identified in 124 of 132 subjects,while were not identified in 8 eyes.For the macular area morphology change,iOCT tips and surgeon judgment rate was inconsistent in 22 eyes (16.7%).For the operation guidance value,change the operation rate of 12/132,accounted for 9.1%.The iOCT imaging quality of high myopia groups was lower than the non-high myopia groups (x2-17.13,P=0.001).Corneal edema and operation time were considered as influencing factors on the quality of the imaging in the non-high myopia groups (r =3.75,6.18;P 0.049,0.013).There were no complications such as endophthalmitis.Conclusions The surgeon can observe morphological changes in the macular area through iOCT which is difficult to be observed by operating microscope and selected reasonable operation method during the surgery.High myopia,corneal edema and operation time affect the image quality.