Cardiac Functional Changes in 8 Patients After Percutaneous Pulmonary Valve Implantation
10.3969/j.issn.1000-3614.2016.07.015
- VernacularTitle:经皮肺动脉瓣植入术后患者心功能的变化8例分析
- Author:
Junyi WAN
;
Minjie LU
;
Gejun ZHANG
;
Shiliang JIANG
;
Zhongying XU
;
Shihua ZHAO
;
Jinglin JIN
;
Huijun SONG
;
Xiangbin PAN
- Publication Type:Journal Article
- Keywords:
Pulmonary valve insufficiency;
Heart catheterization;
Magnetic resonance imaging;
Ventricular function
- From:
Chinese Circulation Journal
2016;31(7):683-686
- CountryChina
- Language:Chinese
-
Abstract:
Objective: To evaluate the changes of left and right ventricular function in patients after percutaneous pulmonary valve implantation (PPVI). Methods: A total of 8 patients with successful PPVI in our hospital from 2014-05-27 to 2015-03-25 were studied. The patients received pre-operative evaluation including clinical symptoms, plasma BNP levels, ECG, chest X-ray, echocardiography, CT and MRI examinations. Post-operative follow-up study was conducted at 6 months after PPVI to compare the ventricular functional changes. Results: The average age in 8 patients was 14-42 (25.4±8.1) years including 7 with tetralogy of Fallot correction and 1 with pulmonary stenosis plasty for 24 years. Echocardiography found that 3 patients with mid to large pulmonary regurgitation and 5 with large regurgitation. Compared with pre-operation, at 6 months after PPIV, all patients had decreased right ventricular end-diastolic diameter (RVEDD) as (44.0±4.8) mm vs (33.6±7.1) mm, right ventricular end-diastolic volume index (RVEDVI) (150.1±25.7) ml/m2 vs (111.4±39.1) ml/m2, RVESVI (107.8±21.5) ml/m2 vs (80.7±22.2) ml/m2 and right ventricular cardiac output (RV-CO) (6.8±1.3) L/min vs (4.9±0.8) L/min, but right ventricular ejection fraction (RVEF) was similar (40.5±6.2) % vs (39.5±9.9) %, P>0.05; while
increased LVEDD (42.9±4.4) mm vs (46.1±3.0) mm, P<0.05, but LVEDVI (61.8±15.0) ml/m2 vs (72.4±17.6) ml/m2, LVESVI (47.8±12.4) ml/m2 vs (41.0±10.4) ml/m2, LVEF (50.9±5.5) % vs (52.8±6.7) % and LV-CO (3.7±1.0) L/min vs (4.2±1.0) L/min were similar, allP>0.05. Conclusion: PPVI may decrease right ventricular preload, improve its reverse remodeling and maintain systolic function at normal level in relevant patients; while the impacts on left ventricular function and geometry should be further studied.