Differences in outcome of cardiac resynchronization therapy between iscehemic cardiomyopathy and non-ischemic cardiomyopathy
10.3760/cma.j.issn.1008-1372.2016.07.004
- VernacularTitle:心脏再同步化治疗对缺血性心肌病和非缺血性心肌病的疗效差异
- Author:
Yuhui HUANG
;
Jian ZHANG
- Publication Type:Journal Article
- Keywords:
Myocardial ischemia/TH;
Cardiomyopathies/TH;
Cardiac pacing,artificial;
Review
- From:
Journal of Chinese Physician
2016;18(7):972-974
- CountryChina
- Language:Chinese
-
Abstract:
The aim of this review is to detect the difference in outcome of cardiac resynchronization therapy (CRT) between ischemic cardiomyopathy (ICM) and non-ischemic cardiomyopathy (NICM).By reviewing some clinical trials of large scale,we found that restore of heart structure and function in NICM was more significant than ICM.However,there were no significant differences in clinical outcome of improving cardiac function and quality of life,decreasing heart failure re-hospitalization and mortality.