Monoexponential, biexponential and stretched-exponential models based diffusion weighted imaging:a comparative study in the differential diagnosis of benign and malignant breast lesions
10.3760/cma.j.issn.1005-1201.2016.05.004
- VernacularTitle:单指数、双指数及拉伸指数模型扩散加权成像参数鉴别乳腺良、恶性病变的价值
- Author:
Yanan JIN
;
Yan ZHANG
;
Jingliang CHENG
;
Yingying WANG
;
Wenrui TANG
- Publication Type:Journal Article
- Keywords:
Breast neoplasms;
Magnetic resonance imaging;
Comparative study
- From:
Chinese Journal of Radiology
2016;50(5):334-338
- CountryChina
- Language:Chinese
-
Abstract:
Objective To investgate the value of various parameters obtained from monoexponential, biexponential, and stretched exponential diffusion?weighted imaging models in the differential diagnosis of breast lesions. Methods A retrospective study performed in 54 patients with pathologically confirmed malignant tumors(n=30), benign lesions(n=34) and normal fibroglandular tissues (n=30). All patients underwent T1WI, T2WI, dynamic enhancement and diffusion weighted MRI with multi?b values at a 3.0 T magnetic resonance imaging unit. All parameters were measured at a workstation. ADC was calculated by using monoexponential analysis(b=0, 800 s/mm2). Slow apparent diffusion coefficient (ADC?slow), fast apparent diffusion coefficient (ADC?fast), and perfusion fraction (f) were calculated using the biexponential model. Distributed diffusion coefficient (DDC) and water molecular diffusion heterogeneity index (α) were obtained from diffusion?weighted images using the stretched exponential model. All parameters were statistically compared among normal fibroglandular tissues, benign lesions and malignant tumors using Kruskal?Wallis rank sum test. Mann?Whitney U test were used for further comparisons between specific group pairs. ADC values were compared with ADC?slow and DDC for different groups by paired Wilcoxon test. Correlations between ADC?value, ADC?slow and DDC were assessed by using Spearman rank correlation coefficient. Receiver operating characteristic curve was used to analyze and compare the ability of these parameters in differentiation of benign and malignant breast lesions. Results The ADC, ADC?slow, f, DDC and α values were significantly different among the normal fibroglandular tissues, benign tumors and malignant tumors (P<0.05). Further differential comparisons of the four parameters between each pair showed that the ADC, ADC?slow, f, DDC and α values were significantly lower in malignant tumors than both in normal fibroglandular tissues and benign tumors(P<0.016 7). The ADC values of normal fibroglandular tissues, benign tumors and malignant tumors were significantly higher than ADC?slow and DDC (P<0.05). The f and DDC had higher area under the receiver operating characteristic curve (0.688 and 0.657 respectively). The optimal cutoff values for ADC, ADC?slow, f, DDC and α were 1.235 × 10-3mm2/s, 0.428 × 10-3mm2/s, 57.8%, 1.175 × 10-3mm2/s and 0.721, respectively. Theαvalue showed higher specificity (65.5%) and the f value had higher sensitivity (82.9%). Conclusion The parameters derived from biexponential and stretched exponential DWI could be helpful for differentiation between benign and malignant breast tumors.