The research and analysis of wireless digital information technology for postoperative analgesia management
10.3760/cma.j.issn.1008-1372.2016.01.025
- VernacularTitle:无线数字信息化技术用于术后患者镇痛管理的研究和分析
- Author:
Feng YAN
;
Jun LI
;
Haojie WANG
;
Jianbing YANG
;
Shuai HAN
;
Qunying DUAN
- Publication Type:Journal Article
- Keywords:
Computer communication networks;
Analgesia;
Pain,postoperative/TH
- From:
Journal of Chinese Physician
2016;18(1):88-91
- CountryChina
- Language:Chinese
-
Abstract:
Objective To compare the clinical efficacy,adverse reactions,and management effect of postoperative intravenous analgesia for patients with postoperative intravenous analgesia with digital information technology and electronic analgesia pump system.Methods Totally 100 patients with postoperative intravenous analgesia (PCIA) were selected from April 2015 to September 2015 with postoperative intravenous analgesia and randomly divided into Wireless analgesic pump system Group (A group) and electronic analgesia pump group (group B),n =50 each group.Pain score (NRS),sedation score (OAA/S),comfort score (BCS),the total number of times and the number of effective press were pressed in patients were observed and compared between two groups after postoperative analgesia 1 hour (T0),4 hour (T1),10 hour (T2),16 hour (T3),and 24 hour (T4).Patients with early adverse reactions,patients and ward medical staff satisfaction,pain pump failure found in the medical staff and effective treatment of adverse events were also observed and compared in two groups.Results There were no significant difference of patients with NRS,OAA/S and BCS in two groups (P > 0.05).Adverse reactions after postoperative analgesia,total number of times and the number of effective press had also no significant difference in two groups (P > 0.05).Two groups of patients with air blockage,incomplete analgesia rate of adverse events was not significantly different (P > 0.05).Medical workers in time [(1.0 ± 0.5) min vs (3.0 ± 2.1) min,P < 0.05],effective processing time [(4.0-± 2.1) min vs (8.0 ± 5.1) min,P < 0.05] in group A was significantly shorter than group B.The patient satisfaction in group A was significantly higher than group B(12.0 ± 4.2 vs 9.0 ± 3.1,P < 0.05).The satisfaction degree of medical staff in group A was also significantly higher than group B(13.0 ±3.1 vs 10.0 ±2.1,P <0.05).Conclusions The digital information technology of wireless analgesic pump is applied to postoperative analgesia for medical workers to standardize management,improve the work efficiency,and increase the satisfaction of patients and medical staffs.