A study on the diagnostic reliability of classification of intertochanteric fractures
	    		
		   		
		   			 
		   		
	    	
    	 
    	10.11958/20160045
   		
        
        	
        		- VernacularTitle:股骨转子间骨折分型诊断的可靠性研究
- Author:
	        		
		        		
		        		
			        		Wanqiang LI
			        		
			        		;
		        		
		        		
		        		
			        		Dou WU
			        		
			        		;
		        		
		        		
		        		
			        		Genqiang ZHENG
			        		
			        		;
		        		
		        		
		        		
			        		Xiaolong MA
			        		
			        		;
		        		
		        		
		        		
			        		Qiang LIU
			        		
			        		
		        		
		        		
		        		
 
			        		
			        		
		        		 
- Publication Type:Journal Article
- Keywords:
        			
	        			
	        				
	        				
			        		
				        		tomography,X-ray computed;
			        		
			        		
			        		
				        		imaging,three-dimensional;
			        		
			        		
			        		
				        		X-ray film;
			        		
			        		
			        		
				        		diagnosis;
			        		
			        		
			        		
				        		AO classification;
			        		
			        		
			        		
				        		Evans-Jensen classification;
			        		
			        		
			        		
				        		intertochanteric fracture
			        		
			        		
	        			
        			
        		
- From:
	            		
	            			Tianjin Medical Journal
	            		
	            		 2016;44(3):274-277
	            	
            	
- CountryChina
- Language:Chinese
- 
		        	Abstract:
			       	
			       		
				        
				        	Objective To compare the diagnostic reliability of AO classification and Evans-Jensen classifications in X ray film and three-dimensional CT reconstruction images intertochanteric fractures, and explore advantage of the three-di?mensional CT. Methods A retrospective study was performed to evaluate 54 patients with intertochanteric fractures. Three orthopaedic surgeons were asked to make assessment of fracture classifications using X ray film and the three-dimen?sional CT images. Agreement test was performed to evaluate interobserver and intraobserver reliability for fracture classifica?tion. Results When X ray film was used, mean Kappa values of interobserver reliability for AO and Evans-Jensen classifi?cations between three surgeons were 0.597 and 0.571, that was medium consistency. While using three-dimensional CT to AO classification, lower Kappa value was 0.411, medium consistency. Evans-Jensen classification, Kappa value was 0.704, highly consistency. Each surgeon respectively using X ray film and three-dimensional CT, the mean Kappa values of AO and Evans-Jensen classification were 0.464, medium consistency and 0.191 (0.160-0.233), weak consistency. Conclusion Both classifications based on X ray film show moderate consistency, using three-dimensional CT does not improve the consis?tency of AO classification. The three-dimensional CT is not applicable in Evans-Jensen classification.